1701 N 10µL Syringe (26s/51/3) [80075]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl gauge: 26s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 N 10µL Syringe (26s/51/5) [80039]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl gauge: 26s needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 SN 10µL Syringe with special needle (**/**/**) [80008]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl gauge: 26s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 N 25µL Syringe (22s/51/2) [80200]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 25 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 N 25µL Syringe (22s/51/3) [80275]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 25 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1702 N 25µL Syringe (22s/51/5) [80239]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 25 µl gauge: 22s needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 SN 25µL Syringe with special needle (**/**/**) [80208]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 25 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 N 50µL Syringe (22s/51/2) [80900]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 N 50µL Syringe (22s/51/3) [80975]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 50 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1705 N 50µL Syringe (22s/51/5) [80939]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 SN 50µL Syringe with special needle (**/**/**) [80908]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 N 100µL Syringe (22s/51/2) [81000]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 N 100µL Syringe (22s/51/3) [81075]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 100 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1710 N 100µL Syringe (22s/51/3), 6p/k [204362]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 100 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1710 N 100µL Syringe (22s/51/5) [81039]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 SN 100µL Syringe with special needle (**/**/**) [81008]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 N 250µL Syringe (22s/51/2) [81100]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 N 250µL Syringe (22s/51/3) [81175]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 250 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1725 N 250µL Syringe (22s/51/5) [81139]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 SN 250µL Syringe with special needle (**/**/**) [81108]
This micro-volume syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 250 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1800 N 10µL Syringe (26s/51/2) [84875]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 10 µl gauge: 26s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1801 SN 10µL Syringe with special needle (**/**/**) [84876]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 10 µl gauge: 26s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1%...
1802 N 25µL Syringe (22s/51/2) [84878]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 25 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1802 SN 25µL Syringe with special needle (**/**/**) [84879]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 25 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1%...
1805 N 50µL Syringe (22s/51/2) [84881]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1805 SN 50µL Syringe with special needle (**/**/**) [84882]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 50 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1%...
1810 N 100µL Syringe (22s/51/2) [84884]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1810 SN 100µL Syringe with special needle (**/**/**) [84885]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 100 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1%...
1825 N 250µL Syringe (22s/51/2) [84887]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1825 SN 250µL Syringe with special needle (**/**/**) [84888]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a cemented needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 250 µl gauge: 22s needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1%...
LTN [^]
1001 LTN 1mL Syringe (22/51/2) [81317]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of...
1001 LTN 1mL Syringe (22/51/3) [81316]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of...
1001.25 LTN 1.25mL Syringe (22/51/2) [82017]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1.25 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1%...
1001.25 LTN 1.25mL Syringe (22/51/3) [82016]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1.25 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1%...
1002 LTN 2.5mL Syringe (22/51/2) [81417]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of...
1002 LTN 2.5mL Syringe (22/51/3) [81416]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of...
1002 LTN 2.5mL Syringe (22/51/5) [81443]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of...
1005 LTN 5mL Syringe (22/51/2) [81517]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of...
1005 LTN 5mL Syringe (22/51/3) [81516]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of...
1005 LTN 5mL Syringe (22/51/5) [81543]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of...
1010 LTN 10mL Syringe (22/51/2) [81617]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of...
1010 LTN 10mL Syringe (22/51/3) [81616]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of...
1010 LTN 10mL Syringe (22/51/5) [81643]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of...
1101 LTN 1mL Syringe (22/51/5) [81343]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of...
1750 LTN 500µL Syringe (22/51/2) [81217]
This micro-volume syringe is for use with gases and liquids and incorporates Luer Tip cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 500 µl gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 LTN 500µL Syringe (22/51/3) [81216]
This micro-volume syringe is for use with gases and liquids and incorporates Luer Tip cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 500 µl gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1750 LTN 500µL Syringe (22/51/5) [81243]
This micro-volume syringe is for use with gases and liquids and incorporates Luer Tip cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 500 µl gauge: 22 needle length: 51 mm point style: 5 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 LTSN 500µL Syringe with special needle (**/**/**) [81214]
This micro-volume syringe is for use with gases and liquids and incorporates Luer Tip cemented needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 500 µl gauge: 22 needle length: user-specific point style: user-specific Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume ...
LTSN [^]
1001 LTSN 1mL Syringe with special needle (**/**/**) [81314]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: user-specific point style: user-specific Technical parameters Accuracy 1%...
1002 LTSN 2.5mL Stříkačka se speciální jehlou (**/**/**) [81414]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: user-specific point style: user-specific Technical parameters Accuracy 1%...
1005 LTSN 5mL Syringe with special needle (**/**/**) [81514]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: user-specific point style: user-specific Technical parameters Accuracy 1%...
1010 LTSN 10mL Syringe with special needle (**/**/**) [81614]
This syringe is for use with gases and liquids and incorporates a cemented needle and TEFLON PTFE-tipped plunger. The needle is cemented into the conical glass luer tip of the barrrel at a point corresponding to the zero graduation mark. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: user-specific point style: user-specific Technical parameters Accuracy 1%...
Luer Tip [^]
1001 LT 1mL Syringe (Luer Tip) [81301]
This syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 1 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1001.25 LT 1.25 mL Syringe (Luer Tip) [82001]
This syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 1.25 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1002 LT 2.5mL Syringe (Luer Tip) [81401]
This syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 2.5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1005 LT 5mL Syringe (Luer Tip) [81501]
This syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 LT 10mL Syringe (Luer Tip) [81601]
This syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 10 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 LT 10µL Syringe (Luer Tip) [80001]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 LT 25µL Syringe (Luer Tip) [80201]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 25 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 LT 50µL Syringe (Luer Tip) [80901]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 50 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 LT 100µL Syringe (Luer Tip) [81001]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 100 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 LT 250µL Syringe (Luer Tip) [81101]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 250 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 LT 500µL Syringe (Luer Tip) [81201]
This micro-volume syringe with Luer tip is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 500 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
Removable Needle [^]
1001 RN 1mL Syringe (22/51/2) [81330]
This syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1001 RN 1mL Syringe (22/51/3) [81365]
This syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1001 RN 1mL Syringe (Needle not included) [7649-01]
This syringe is for use with gases and liquids and incorporates a TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 1 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1001 RNCP 1mL Syringe (22/19/3) for Valvco VISF-1 [81331]
Syringe for HPLC manual injection for Valvco VISF-1 volume: 1 ml gauge: 22 needle length: 19 mm
1002 RN 2.5mL Syringe (22/51/2) [81430]
This syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1002 RN 2.5mL Syringe (Needle not included) [7650-01]
This syringe is for use with gases and liquids and incorporates a TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 2.5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1002 RNCP 2.5mL Syringe (22/19/3) for Valvco VISF-1 [81431]
Syringe for HPLC manual injection for Valvco VISF-1 volume: 2.5 ml gauge: 22 needle length: 19 mm
1005 RN 5mL Syringe (22/51/2) [81530]
This syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1005 RN 5mL Syringe (Needle not included) [7651-01]
This syringe is for use with gases and liquids and incorporates a TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1005 RNCP 5mL Syringe (22/19/3) for Valvco VISF-1 [81531]
Syringe for HPLC manual injection for Valvco VISF-1 volume: 5 ml gauge: 22 needle length: 19 mm
1010 RN 10mL Syringe (22/51/2) [81630]
This syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 RN 10mL Syringe (Needle not included) [7652-01]
This syringe is for use with gases and liquids and incorporates a TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 10 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 RNCP 10mL Syringe (22/19/3) for Valvco VISF-1 [81631]
Syringe for HPLC manual injection for Valvco VISF-1 volume: 10 ml gauge: 22 needle length: 19 mm
1701 RN 10µL Syringe (26s/51/2) [80030]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl gauge: 26s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 RN 10µL Syringe (32/51/3) [80014]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 µl gauge: 32 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 RN 10µL Syringe (Needle not included) [7653-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 10 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1701 RNFS 10µL Syringe (.17/100/3) [87404]
Fused Silica Syringe for ON COLUMN injection volume: 10 µl „gauge“: 0.17 mm needle length: 100 mm „point style“: 3
1701 RNR 10µL Syringe (22s/51/3) [80065]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 10 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1701 RNW 10µL Syringe (25s/50/3) for WATERS U6K [80038]
Gastight Syringe for the WATERS U6K Injection Valve volume: 10 µL gauge: 25s needle length: 50 mm
1702 RN 25µL Syringe (22s/51/2) [80230]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 25 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 RN 25µL Syringe (Needle not included) [7654-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. The syringe is suitable for LC autosamplers Gynkotek Gina/Dionex ASI-100. volume: 25 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 RNR 25µL Syringe (22s/51/3) [80265]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 25 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1702 RNW 25µL Syringe (25s/50/3) for WATERS U6K [80238]
Gastight Syringe for the WATERS U6K Injection Valve volume: 25 µL gauge: 25s needle length: 50 mm
1705 RN 50uL Syringe (Needle not included) [7655-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 50 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 RN 50µL Syringe (22s/51/2) [80930]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 RNCP 50µL Syringe (22s/19/3) for Valvco VISF-1 [80931]
Syringe for HPLC manual injection for Valvco VISF-1 volume: 50 µL gauge: 22s needle length: 19 mm
1705 RNFS 50µL Syringe (.23/100/3) [200470]
Fused Silica Syringe for ON COLUMN injection volume: 50 µl „gauge“: 0.23 mm needle length: 100 mm „point style“: 3
1705 RNR 50µL Syringe (22s/51/3) [80965]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 50 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1705 RNW 50µL Syringe (25s/50/3) for WATERS U6K [80938]
Gastight Syringe for the WATERS U6K Injection Valve volume: 50 µL gauge: 25s needle length: 50 mm
1710 RN 100uL Syringe (Needle not included) [7656-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. Suitable for Shimadzu SIL-6A LC Autosampler. volume: 100 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 RN 100µL Syringe (22s/51/2) [81030]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 RNFS 100µL Syringe (.23/100/3) [200480]
Fused Silica Syringe for ON COLUMN injection volume: 100 µl „gauge“: 0.23 mm needle length: 100 mm „point style“: 3
1710 RNR 100µL Syringe (22s/51/3) [81065]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 100 µl gauge: 22s needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1710 RNW 100µL Syringe (25s/50/3) for WATERS U6K [81038]
Gastight Syringe for the WATERS U6K Injection Valve volume: 100 µL gauge: 25s needle length: 50 mm
1725 RN 250uL Syringe (Needle not included) [7657-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. The syringe is suitable for LC autosamplers Gynkotek Gina/Dionex ASI-100. volume: 250 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 RN 250µL Syringe (22s/51/2) [81130]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 RNR 250µL Syringe (22/51/3) [81165]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 250 µl gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1725 RNW 250µL Syringe (25s/50/3) for WATERS U6K [81138]
Gastight Syringe for the WATERS U6K Injection Valve volume: 250 µL gauge: 25s needle length: 50 mm
1750 RN 500uL Syringe (Needle not inlcuded) [7658-01]
This micro-volume syringe is for use with gases and liquids and incorporates TEFLON PTFE-tipped plunger. Plunger is replaceable. Needle is not included. volume: 500 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 RN 500µL Syringe (22/51/2) [81230]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 500 µl gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 RNR 500µL Syringe (22/51/3) [81265]
This micro-volume syringe is for use with gases and liquids and incorporates a removable needle and TEFLON PTFE-tipped plunger. Plunger is replaceable. Suitable for Rheodyne, Valvco VISF-2, Beckman/Altex and SSI Injection Valves. volume: 500 µl gauge: 22 needle length: 51 mm point style: 3 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1801 RN 10uL Syringe (Needle not included) [7659-01]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. Needle is not included. volume: 10 µl gauge: 26s Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1801 RN 10µL Syringe (26s/51/2) [84877]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a removable needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 10 µl gauge: 26s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1801 RNFS 10µL Syringe (.17/100/3) [87405]
Fused Silica Syringe for ON COLUMN injection with reinforced plunger volume: 10 µl „gauge“: 0.17 mm needle length: 100 mm „point style“: 3
1801 RNW 10µL Syringe (25s/50/3) for WATERS U6K [84977]
Gastight Syringe for the WATERS U6K Injection Valve volume: 10 µL gauge: 25s needle length: 50 mm
1802 RN 25uL Syringe (Needle not included) [7660-01]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. Needle is not included. volume: 25 µl gauge: 22s Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1802 RN 25µL Syringe (22s/51/2) [84880]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a removable needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 25 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1802 RNW 25µL Syringe (25s/50/3) for WATERS U6K [84980]
Gastight Syringe for the WATERS U6K Injection Valve volume: 25 µL gauge: 25s needle length: 50 mm
1805 RN 50uL Syringe (Needle not included) [7661-01]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. Needle is not included. volume: 50 µl gauge: 22s Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1805 RN 50µL Syringe (22s/51/2) [84883]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a removable needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1805 RNW 50µL Syringe (25s/50/3) for WATERS U6K [84983]
Gastight Syringe for the WATERS U6K Injection Valve volume: 50 µL gauge: 25s needle length: 50 mm
1810 RN 100uL Syringe (Needle not included) [7662-01]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. Needle is not included. volume: 100 µl gauge: 22s Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1810 RN 100µL Syringe (22s/51/2) [84886]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a removable needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1810 RNW 100µL Syringe (25s/50/3) for WATERS U6K [84986]
Gastight Syringe for the WATERS U6K Injection Valve volume: 100 µL gauge: 25s needle length: 50 mm
1825 RN 250uL Syringe (Needle not included) [7663-01]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. Needle is not included. volume: 250 µl gauge: 22s Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1825 RN 250µL Syringe (22s/51/2) [84889]
This micro-volume syringe is for use with gases and liquids. The syringe incorporates a removable needle and a reinforced PTFE-tipped plunger. Plunger assemblies and glass barrel are replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale...
1825 RNW 250µL Syringe (25s/50/3) for WATERS U6K [84989]
Gastight Syringe for the WATERS U6K Injection Valve volume: 250 µL gauge: 25s needle length: 50 mm
Sample Lock [^]
1001 SL 1mL Syringe (22/51/2) [81356]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 1 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1002 SL 2.5mL Syringe (22/51/2) [81456]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 2.5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1005 SL 5mL Syringe (22/51/2) [81556]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 5 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1010 SL 10mL Syringe (22/51/2) [81656]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 10 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1025 SL 25mL Syringe (22/51/2) [86326]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 25 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1050 SL 50mL Syringe (22/51/2) [86336]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1100 SL 100mL Syringe (22/51/2) [86346]
This syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 ml gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total...
1705 SL 50µL Syringe (22s/51/2) [80956]
This micro-volume syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 50 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1710 SL 100µL Syringe (22s/51/2) [81056]
This micro-volume syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 100 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1725 SL 250µL Syringe (22s/51/2) [81156]
This micro-volume syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 250 µl gauge: 22s needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1%...
1750 SL 500µL Syringe (22/51/2) [81256]
This micro-volume syringe with on/off valve is for use with gases. Used for headspace, environmental sample collection and storage, sample spiking. This syringe has TEFLON PTFE-tipped plunger. Plunger is replaceable. volume: 500 µl gauge: 22 needle length: 51 mm point style: 2 Technical parameters Accuracy 1% of nominal volume Precision 1%...
TLL [^]
1001 TLL 1mL Syringe with slots (Needle not included) [81327]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 1 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1001 TLL 1mL Syringe without slots (needle not included) [81320]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 1 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1002 TLL 2.5mL Syringe with slots (Needle not included) [81427]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 2.5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1002 TLL 2.5mL Syringe without slots (needle not included) [81420]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 2.5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1005 TLL 5mL Syringe with slots (Needle not included) [81527]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1005 TLL 5mL Syringe without slots (needle not included) [81520]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 5 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 TLL 10mL Syringe with slots (Needle not included) [81627]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 10 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 TLL 10mL Syringe without slots (needle not included) [81620]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 10 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1010 TLL-XL 10mL Syringe [201827]
60 mm Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 10 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1025 TLL 25mL Syringe with slots (Needle not included) [82527]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 25 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1025 TLL 25mL Syringe without flange, with slots [82525]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 25 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1025 TLL 25mL Syringe without flange, without slots [82521]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 25 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1025 TLL 25mL Syringe without slots (needle not included) [82520]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 25 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1050 TLL 50mL Syringe with slots (Needle not included) [85027]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 50 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1050 TLL 50mL Syringe without flange, with slots [85025]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 50 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1050 TLL 50mL Syringe without flange, without slots [85021]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 50 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1050 TLL 50mL Syringe without slots (needle not included) [85020]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 50 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1100 TLL 100mL Syringe without slots (needle not included) [86020]
Kel-F(CTFE) Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 100 ml Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1702 TLLX 25µL Syringe with stop (needle not included) [80222]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. volume: 25 µl Technical parameters Accuracy 1% of nominal...
1705 TLL 50µL Syringe with slots [80927]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 50 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 TLL 50µL Syringe without slots (needle not included) [80920]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 50 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1705 TLLX 50µL Syringe with stop (needle not included) [80922]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. volume: 50 µl Technical parameters Accuracy 1% of nominal...
1705 TLLXB 50µL Syringe with stop and backbushing [80947]
Teflon Luer Lock Syringe with stop and backbushing Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms. Back-bushing syringes increase plunger tip life, maintain proper plunger alignment and reduce the particles generated...
1710 TLL 100µL Syringe with slots [81027]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 100 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 TLL 100µL Syringe without slots (needle not included) [81020]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 100 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1710 TLLX 100µL Syringe with stop (needle not included) [81022]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. volume: 100 µl Technical parameters Accuracy 1% of nominal...
1725 TLL 250µL Syringe with slots [81127]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 250 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 TLL 250µL Syringe without slots (needle not included) [81120]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 250 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1725 TLLX 250µL Syringe with stop (needle not included) [81122]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. volume: 250 µl Technical parameters Accuracy 1% of nominal...
1750 TLL 500µL Syringe with slots [81227]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. Needle is not included. volume: 500 µl Technical parameters Accuracy 1% of nominal volume
1750 TLL 500µl Syringe without slots (needle not included) [81220]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 500 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 TLL-XL 500µL Syringe [201807]
60 mm Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger is replaceable. volume: 500 µl Technical parameters Accuracy 1% of nominal volume Precision 1% at 80% of total scale volume
1750 TLLX 500µL Syringe with stop (needle not included) [81222]
Teflon Luer Lock Syringe Male luer taper with nickel-plated brass hub accepts, and lock in place, luer hub needles and connectors. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. volume: 500 µl Technical parameters Accuracy 1% of nominal...
– [^]
1001 AD 1mL Syringe [201200]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 1 ml
1001 C 1mL Syringe [81360]
Syringe Cheminert This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200 and Spectra-Physics/ThermoFinnigan LC autosamplers AS100/300, AS1000/3000/3500.
1001 C-XP 1mL Syringe [201760]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1001 DAD 1mL Syringe [201700]
Syringe DAD (Diluter AccuDil) with stop M8×0.75 male fitting with M6×1 side port. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included.
1001 DX 1mL Syringe [81326]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 1 ml Technical parameters Accuracy 1% of nominal volume Precision 1%...
1002 AD 2.5mL Syringe [201250]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 2.5 ml
1002 C 2.5mL Syringe [81460]
Syringe Cheminert This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200 and Spectra-Physics/ThermoFinnigan LC autosamplers SP8780/8875/8880, AS100/300, AS1000/3000/3500.
1002 C-XP 2.5mL Syringe [201770]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1005 AD 5mL Syringe [201300]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 5 ml
1005 C 5mL Syringe [81560]
Syringe Cheminert This syringe has 1/4"-28 UNF, male fitting. Needle is not included.
1005 C-XP 5mL Syringe [201780]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1010 AD 10mL Syringe [201350]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 10 ml
1010 C 10mL Syringe [81660]
Syringe Cheminert This syringe has 1/4"-28 UNF, male fitting. Needle is not included.
1010 W 10mL Syringe - Manual Priming for Waters Pumps [81610]
Manual Priming Syringe for WATERS Pumps volume: 10 ml needle not included
1025 AD 25mL Syringe [201400]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 25 ml
1701 CX 10µL Syringe with stop [80062]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1702 CX 25µL Syringe with stop [80262]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1702 DX 25µL Syringe [80226]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 25 µl Technical parameters Accuracy 1% of nominal volume Precision 1%...
1705 AD 50µL Syringe [201000]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 50µL
1705 C-XP 50µL Syringe [201720]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1705 CX 50µL Syringe with stop [80962]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1705 DAD 50µL Syringe [201500]
Syringe DAD (Diluter AccuDil) with stop M8×0.75 male fitting with M6×1 side port. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included.
1705 DX 50µL Syringe [80926]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 50 µl Technical parameters Accuracy 1% of nominal volume Precision 1%...
1710 AD 100µL Syringe [201050]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. The syringe is suitable for LC Autosamplers Kontron 360, 460 a 465. volume 100µL
1710 C-XP 100µL Syringe [201730]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1710 CX 100µL Syringe with stop [81062]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1710 DAD 100µL Syringe [201550]
Syringe DAD (Diluter AccuDil) with stop M8×0.75 male fitting with M6×1 side port. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included.
1710 DX 100µL Syringe [81026]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 100 µl Technical parameters Accuracy 1% of nominal volume Precision 1%...
1725 AD 250µL Syringe [201100]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 250µL
1725 C-XP 250µL Syringe [201740]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1725 CX 250µL Syringe with stop [81162]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1725 DAD 250µL Syringe [201600]
Syringe DAD (Diluter AccuDil) with stop M8×0.75 male fitting with M6×1 side port. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included.
1725 DX 250µL Syringe [81126]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 250 µl Technical parameters Accuracy 1% of nominal volume Precision 1%...
1750 AD 500µL Syringe [201150]
Syringe AccuDil with stop M8×0.75, male fitting. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included. volume 500µL
1750 C-XP 500µL Syringe [201750]
Syringe Cheminert 30 mm This syringe has 1/4"-28 UNF, male fitting. Needle is not included. Compatible with many handling instruments.
1750 CX 500µL Syringe with stop [81262]
Syringe Cheminert with stop This syringe has 1/4"-28 UNF, male fitting. The plunger stop incorporates a 6–32 UNC female thread on the end of the stop. Needle is not included. Suitable for Perkin-Elmer LC Autosamplers Series 200.
1750 DAD 500µL Syringe [201650]
Syringe DAD (Diluter AccuDil) with stop M8×0.75 male fitting with M6×1 side port. Used with MICROLAB 1000 PLUS diluter/dispenser. Needle not included.
1750 DX 500µL Syringe [81226]
Teflon Luer Lock syringe, male fitting with M6×1 female, side port. Plunger stop incorporates a 6–32 UNC female thread on the end of the stop to allow attachment to drive arm mechanisms, such as on the MICROLAB 500 Series diluters/dispensers. Needle is not included. volume: 500 µl Technical parameters Accuracy 1% of nominal volume Precision 1%...