Fittings and tubings - Products - Chromservis.cz
Section: Homepage » Laboratory » Chromatography » Accessories » HPLC » Fittings and tubings
Please select a product branch from the tree below.
C [^]
Clean-Cut Tubing Cutter (PEEK, PTFE, ETFE) [JR-797]
Cuts PEEK, PTFE, ETFE, and other polymeric tubing No distortion of OD or closing of ID Safety lock to secure the blade It is difficult to obtain burr-free perpendicular cuts on polymeric tubing, but right angles and clean cuts are essential in LC to avoid leaks. The Clean-Cut is a tool for the most demanding LC applications, making clean, perpendicular cuts without distorting the...
F [^]
Fitting 1/16", PEEK, natural, length 17.1 mm, 10-32, 5/pkg [JR-5504-5]
Fingertight up to 350 bar (5000 psi) Excellent chemical resistance Machined, not molded – One-piece – no ferrule required Biocompatible – 10–32 threads, for 1/16" tubing
Fitting 1/16", PEEK, natural, length 22 mm, 10-32, 5/pkg [JR-5502-5]
Fingertight up to 350 bar (5000 psi) Excellent chemical resistance Machined, not molded – One-piece – no ferrule required Biocompatible – 10–32 threads, for 1/16" tubing
Fitting 1/16", PEEK, natural, length 25.1 mm, 10-32, 5/pkg [JR-5507-5]
Fingertight up to 350 bar (5000 psi) Excellent chemical resistance Machined, not molded – One-piece – no ferrule required Biocompatible – 10–32 threads, for 1/16" tubing
Fitting 1/16", PEEK, natural, length 28.1 mm, 10-32, 5/pkg [JR-5508-5]
Fingertight up to 350 bar (5000 psi) Excellent chemical resistance Machined, not molded – One-piece – no ferrule required Biocompatible – 10–32 threads, for 1/16" tubing
Fitting 1/16", PEEK, one-piece natural, 10-32, 5/pkg [JR-55020-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
Fitting, PEEK, one-piece black, 10-32, 5/pkg [JR-55021-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
Fitting, PEEK, one-piece blue, 10-32, 5/pkg [JR-55024-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
Fitting, PEEK, one-piece green, 10-32, 5/pkg [JR-55025-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
Fitting, PEEK, one-piece red, 10-32, 5/pkg [JR-55022-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
Fitting, PEEK, one-piece yellow, 10-32, 5/pkg [JR-55023-5]
To identify various tubing lines the PEEK fingertight fittings are available in six colors. The coloration pigments are carefully chosen to contain no heavy metals or hazardous chemicals. PEEK fingertight fittings are rated to 350 bar (5000 psi) and can be used in virtually any type of HPLC fitting detail on the market with 10–32 thread. Features Fingertight up to 350 bar (5000 psi) Excellent...
N [^]
No-Ox fitting kit 1/8" [JR-6140]
Features Low permeability prevents "re-gassing Excellent chemical resistance Most HPLC installations use PTFE tubing for internal low-pressure transfer lines, since PTFE is easy to use and extremely chemically inert. However, PTFE- and PTFE-like polymers have micro pores which allow gases to diffuse freely, to the extent that solvent degassers are often based on that property –...
T [^]
Tubing Cutter for metal OD 1/16" and 1/8" tubings [JR-792]
For 1/16" and 1/8" SS tubing Makes a smooth, uniform cut Minimal deburring and/or reaming required Easily replaceable cutting wheel This is the ideal tool for cutting 1/16“ and 1/8“ stainless steel tubing with an ID >0.5 mm for non-critical connections. The smooth, uniform cuts require little deburring or reaming . The easily replaced cutting wheel scores the tubing.
Tubing Pliers for metal tubings of 1/16" and 1/8" OD [JR-796]
For easy cutting 1/16" OD SS tubing off a coil Reaches „hard to get“ places in an HPLC system The plier type of cutter can be used for quick cuts for non-critical applications or at „hard to get“ places. However, for scientific equipment the use of Pre-Cut and cleaned tubing is strongly recommended.
Tubing, No-Ox, 1/8'' x 1.65 mm ID, 10 m/pkg [JR-T-6130-M10]
Features Low permeability prevents "re-gassing Excellent chemical resistance Most HPLC installations use PTFE tubing for internal low-pressure transfer lines, since PTFE is easy to use and extremely chemically inert. However, PTFE- and PTFE-like polymers have micro pores which allow gases to diffuse freely, to the extent that solvent degassers are often based on that property –...
Tubing, No-Ox, 1/8'' x 1.65 mm ID, 3 m/pkg [JR-T-6130-M3]
Features Low permeability prevents "re-gassing Excellent chemical resistance Most HPLC installations use PTFE tubing for internal low-pressure transfer lines, since PTFE is easy to use and extremely chemically inert. However, PTFE- and PTFE-like polymers have micro pores which allow gases to diffuse freely, to the extent that solvent degassers are often based on that property –...
Tubing, PEEK, 1/16'' OD X 0.13 mm ID, red striped, 10 m/pkg [JR-T-5999-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.13 mm ID, red striped, 3 m/pkg [JR-T-5999-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.18 mm ID, yellow striped, 10 m/pkg [JR-T-6000-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.18 mm ID, yellow striped, 3 m/pkg [JR-T-6000-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.25 mm ID, blue striped, 10 m/pkg [JR-T-6001-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.25 mm ID, blue striped, 3 m/pkg [JR-T-6001-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.50 mm ID, orange striped, 10 m/pkg [JR-T-6002-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.50 mm ID, orange striped, 3 m/pkg [JR-T-6002-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.75 mm ID, green striped, 10 m/pkg [JR-T-6003-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/16'' OD x 0.75 mm ID, green striped, 3 m/pkg [JR-T-6003-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/8'' OD x 1.59 mm ID, natural, 10 m/pkg [JR-T-6004-M10]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
Tubing, PEEK, 1/8'' OD x 1.59 mm ID, natural, 3 m/pkg [JR-T-6004-M3]
PEEK tubing has the strength required to withstand continuous use at HPLC pressure without swelling or bursting. The dense polymer structure of VICI Jour PEEK tubing eliminates the permeability to organic solvents that causes other polymer tubing, such as ETFE, to ”sweat”. VICI Jour tubing is color coded for easy identification of the ID. We recommend „Striped Color-Coded“ tubing. It...
U [^]
UHPLC Filter, SS, In-Line ID 0.25 mm, complete, frit SS 0.5 µm [JR-68230-05]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....
UHPLC Filter, SS, In-Line ID 0.25 mm, complete, frit SS 2 µm [JR-68230-2]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....
UHPLC Filter, SS, In-Line ID 0.25 mm, complete, frit SS 5 µm [JR-68230-5]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....
UHPLC Filter, SS, In-Line ID 0.75 mm, complete, frit SS 0.5 µm [JR-68231-05]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....
UHPLC Filter, SS, In-Line ID 0.75 mm, complete, frit SS 2 µm [JR-68231-2]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....
UHPLC Filter, SS, In-Line ID 0.75 mm, complete, frit SS 5 µm [JR-68231-5]
The Vici Jour SS In-Line Filter has virtually no hold-up volume and can be used in various applications without significant band broadening or loss of efficiency. The 0.25 mm bore versions are intended for analytical use between autosampler/injection valve and column. The 0.75 mm bore versions are suitable for higher flow rates in semi prep systems or for solvent supply from pump to autosampler....





eVol® XR Digitally Controlled Syringe