EN CZ SK RU BG

Other accessories - Products - Chromservis.cz

Section: Homepage » Laboratory » Chromatography » Accessories » GC » Other accessories

Please select a product branch from the tree below.

C F I M S

C [^]

Ceramic Scoring Wafers, with holders, 5/pk [R*20116]
Ceramic Scoring Wafers, with holders, 5/pk

The ceramic scoring wafer has four straight scoring edges for cutting fused silica tubing and four serrated edges for cutting MXT® metal capillary columns. Note: The pack includes holders.

F [^]

Fixed Outlet Splitter 1:1 [SGE*1861460]
Fixed Outlet Splitter 1:1

The Fixed Outlet Splitter is recommended for splitting the flow from a capillary column between two detectors. The kit consists of a special Glass Lined Tubing (GLT™) splitter union, tubing and all ferrules required for installation. Splitter is intended for capillaries 0.1 to 0.32 mm ID.

Fixed Outlet Splitter 1:10 [SGE*1861462]
Fixed Outlet Splitter 1:10

The Fixed Outlet Splitter is recommended for splitting the flow from a capillary column between two detectors. The kit consists of a special Glass Lined Tubing (GLT™) splitter union, tubing and all ferrules required for installation. Splitter is intended for capillaries 0.1 to 0.32 mm ID.

Fixed Outlet Splitter 1:5 [SGE*1861461]
Fixed Outlet Splitter 1:5

The Fixed Outlet Splitter is recommended for splitting the flow from a capillary column between two detectors. The kit consists of a special Glass Lined Tubing (GLT™) splitter union, tubing and all ferrules required for installation. Splitter is intended for capillaries 0.1 to 0.32 mm ID.

Fixed Outlet Splitter with user determined ration [SGE*123630]
Fixed Outlet Splitter with user determined ration

The Fixed Outlet Splitter is recommended for splitting the flow from a capillary column between two detectors. The kit consists of a special Glass Lined Tubing (GLT™) splitter union, tubing and all ferrules required for installation. Splitter is intended for capillaries 0.1 to 0.32 mm ID.

I [^]

Inlet Liner Removal Tool, 3/pk [R*20181]
Inlet Liner Removal Tool, 3/pk

Easily removes liner from injector – no more burned fingers. Made from high-temperature silicone. Won’t chip or crack the liner.

Inlet Seals, Dual Vespel Ring, 0.8mm Gold Plated Cross Disk [R*22083]
Inlet Seals, Dual Vespel Ring, 0.8mm Gold Plated Cross Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 0.8mm Gold Plated Disk [R*21240]
Inlet Seals, Dual Vespel Ring, 0.8mm Gold Plated Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 0.8mm Siltek Treated Cross Disk [R*22085]
Inlet Seals, Dual Vespel Ring, 0.8mm Siltek Treated Cross Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 0.8mm Siltek Treated Disk [R*21242]
Inlet Seals, Dual Vespel Ring, 0.8mm Siltek Treated Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 0.8mm Stainless Steel Cross Disk [R*22087]
Inlet Seals, Dual Vespel Ring, 0.8mm Stainless Steel Cross Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 0.8mm Stainless Steel Disk [R*21238]
Inlet Seals, Dual Vespel Ring, 0.8mm Stainless Steel Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 1.2mm Gold Plated Disk [R*21246]
Inlet Seals, Dual Vespel Ring, 1.2mm Gold Plated Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 1.2mm Siltek Treated Disk [R*21248]
Inlet Seals, Dual Vespel Ring, 1.2mm Siltek Treated Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

Inlet Seals, Dual Vespel Ring, 1.2mm Stainless Steel Disk [R*21244]
Inlet Seals, Dual Vespel Ring, 1.2mm Stainless Steel Disk

Washerless, Leak-Tight Seal for Agilent GCs ensures better tightness and easier handling than original part. Prevents oxygen from permeating the carrier gas, increasing column lifetime. Vespel® ring in top surface reduces operator variability by requiring minimal torque to seal. Vespel® ring in bottom surface simplifies installation—eliminates the washer. In Agilent split/splitless...

M [^]

MS/FID Splitter Kit [SGE*123710]
MS/FID Splitter Kit

MS/FID Splitter Kit includes a complete set of restrictors, SilTite metal ferrules and silica tubing. Note: Not suitable for use with 0.1mm ID columns.

S [^]

Septum Puller [R*20117]
Septum Puller

The tool usse hooked end for removing septa and O-rings. Pointed end works well for removing stuck ferrules or debris.

SilTite nut 10/32", 0.8mm ID 5/pk [SGE*073224]
SilTite nut 10/32", 0.8mm ID 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

SilTite nut, Agilent Injector, 5/pk [SGE*073226]
SilTite nut, Agilent Injector, 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

SilTite nut, Shimadzu Injector, 5/pk [SGE*073232]
SilTite nut, Shimadzu Injector, 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

SilTite nut, Shimadzu Std. Interface, 5/pk [SGE*073233]
SilTite nut, Shimadzu Std. Interface, 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

SilTite nut, Thermo Finnigan, 5/pk [SGE*073230]
SilTite nut, Thermo Finnigan, 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

SilTite nut, Varian, 5/pk [SGE*073231]
SilTite nut, Varian, 5/pk

SilTite nuts for use with SilTite Ferrules. Eliminates leaks (See figures below) Never needs re-tightening, even after temperature cycling Ferrule remains permanently fixed to the column but does not adhere to the SilTite nut No contamination from Vespel or graphite materials – 100% metal Ideal for high pressure applications Also available for injector interfaces >500°C...

Product catalog



Your purchasing basket does not include any item

Product news

eVol XR

eVol XReVol® XR Digitally Controlled Syringe

New eVol® XR Digitally Controlled Syringe enables use of the 1ml eVol® syringe. Use eVol® XR with the complete eVol® syringe range from 5µL to 1ml (5μl, 50μl, 100μl, 500μl, 1.0ml). Ask for more information.