Ferrules - Products - Chromservis.cz
Section: Homepage » Laboratory » Chromatography » Accessories » GC » Ferrules
Please select a product branch from the tree below.
Graphite [^]
Graphite Ferrule 1/16 Long 0.4mm ID (10/pk)"" [C*211104]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Long 0.5mm ID (10/pk)"" [C*211105]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Long 0.8mm ID (10/pk)"" [C*211108]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Long 1.0mm ID (10/pk)"" [C*211110]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Long 1.2mm ID (10/pk)"" [C*211112]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Long 1/16"" ID (10/pk)"" [C*211100]
Capillary Column Ferrules 1/16" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary Column...
Graphite Ferrule 1/16 Short 0.4mmID for Dani/Agilent GC (10/pk)"" [C*211164]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Graphite Ferrule 1/16 Short 0.5mmID for Dani/Agilent GC (10/pk)"" [C*211165]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Graphite Ferrule 1/16 Short 0.8mmID for Dani/Agilent GC (10/pk)"" [C*211168]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Graphite Ferrule 1/16 Short 1.0mmID for Dani/Agilent GC (10/pk)"" [C*211160]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Graphite ferrule 1/16 Short 1/16"" ID for GC Dani/Agilent (10/pk)"" [C*211170]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Graphite Ferrule 1/8 Long 0.4mm ID (10/pk)"" [C*211204]
Capillary Column Ferrules 1/8" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule 1/8 Long 0.5mm ID (10/ks)"" [C*211205]
Capillary Column Ferrules 1/8" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule 1/8 Long 0.8mm ID (10/pk)"" [C*211208]
Capillary Column Ferrules 1/8" typ „LONG“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.25mm ID 0.5mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule M4 for Thermo 0.25mm ID (10/pk) [C*211982-10]
Capillary Column Ferrules typ M4 for Gc Thermo injectors from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.25mm for Capillary Column with ID 0.10mm ID 0.35mm for Capillary Column with ID 0.18–0.25mm ID 0.45mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule M4 for Thermo 0.35mm ID (10/pk) [C*211983-10]
Capillary Column Ferrules typ M4 for Gc Thermo injectors from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.25mm for Capillary Column with ID 0.10mm ID 0.35mm for Capillary Column with ID 0.18–0.25mm ID 0.45mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule M4 for Thermo 0.45mm ID (10/pk) [C*211984-10]
Capillary Column Ferrules typ M4 for Gc Thermo injectors from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.25mm for Capillary Column with ID 0.10mm ID 0.35mm for Capillary Column with ID 0.18–0.25mm ID 0.45mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
Graphite Ferrule M4 for Thermo 0.8mm ID (10/pk) [C*211988-10]
Capillary Column Ferrules typ M4 for Gc Thermo injectors from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.25mm for Capillary Column with ID 0.10mm ID 0.35mm for Capillary Column with ID 0.18–0.25mm ID 0.45mm for Capillary Column with ID 0.32mm ID 0.8mm for Capillary Column with ID 0.53mm
PTFE [^]
PTFE Ferrule 1/16 Long 0.3mm ID (10/pk)"" [C*214103]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/16 Long 0.4mm ID (10/pk)"" [C*214104]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/16 Long 0.8mm ID (10/pk)"" [C*214108]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/16 Long 1.0mm ID (10/pk)"" [C*214110]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/16 Long 1.2mm ID (10/pk)"" [C*214112]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/16 Long 1/16"" ID (10/pk)"" [C*214100]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/4 Long 1/4"" ID (10/pk)"" [C*214400]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/8 Long 1/8"" ID (10/pk)"" [C*214200]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/8 Long 4mm ID (10/pk)"" [C*214204]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/8 Long 4mm ID (10/pk)"" [C*214205]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferrule 1/8 Long 8mm ID (10/pk)"" [C*214208]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
PTFE Ferulle 1/16 Long 0.5mm ID (10/pk)"" [C*214105]
Capillary Column Ferrules 1/16" typ „SHORT“ from High-purity Graphite Precision Formed Upper temperature 450°C Reusable of not overtightened ID 0.4mm for Capillary Column with ID 0.18mm ID 0.5mm for Capillary Column with ID 0.25–0.32mm ID 0.8mm for Capillary Column with ID 0.53mm ID 1.0mm for Capillary...
Siltite [^]
SilTite Ferrule for 0.25mm ID capillary (Thermo), 10/pk [SGE*073330]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.25mm ID capillary, 10/pk [SGE*073220]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.25mm ID capillary, 10/pk [SGE*073227]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.32mm ID capillary (Thermo), 10/pk [SGE*073331]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.32mm ID capillary, 10/pk [SGE*073221]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.32mm ID capillary, 10/pk [SGE*073228]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.53mm ID capillary (Thermo), 10/pk [SGE*073332]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.53mm ID capillary, 10/pk [SGE*073222]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 0.53mm ID capillary, 10/pk [SGE*073229]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 1/32" ID capillary (Shimadzu), 10/pk [SGE*073235]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 1/32" ID capillary (Thermo), 10/pk [SGE*073333]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
SilTite Ferrule for 1/32" ID capillary, 10/pk [SGE*073219]
SGE has developed a metal ferrule specifically for use with fused silica GC columns. Combining a specially designed ferrule and nut system, the SilTite ferrules must be used in conjunction with this special nut that is supplied with the ferrules. The geometry of the nut and ferrule combination makes it possible to swage the end of the ferrule to the fused silica tubing. This creates a leak-free...
Vespel [^]
Vespel Ferrule 1/16 Long 0.4mm ID (10/pk)"" [C*212104]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 0.5mm ID (10/pk)"" [C*212105]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 0.8mm ID (10/pk)"" [C*212108]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 1.0mm ID (10/pk)"" [C*212110]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 1.2mm ID (10/pk)"" [C*212112]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 0.3mm ID (10/pk)"" [C*212103]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Long 1/16"" OD (10/pk)"" [C*212100]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Short 0.4mm ID (10/pk)"" [C*212164]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Short 0.5mm ID (10/pk)"" [C*212165]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/16 Short 0.5mm ID (10/pk)"" [C*212168]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/8 Long 0.4mm ID (10/pk)"" [C*212204]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/8 Long 0.5mm ID (10/pk)"" [C*212205]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel Ferrule 1/8 Long 0.8mm ID (10/pk)"" [C*212208]
100% high temperature DuPont polyimide max. temperature 350°C Fairly hard, tends to seal pernamently to the column ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite [^]
Vespel/Graphite 1/16 Long 0.8mm ID (10/pk)"" [C*213108]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite 1/16 Long 1.2mm ID (10/pk)"" [C*213112]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 0.3mm ID (10/pk)"" [C*213103]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 0.4mm ID ""two-hole"" (10/pk)"" [C*213124]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 0.5mm ID ""two-hole"" (10/pk)"" [C*213125]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 0.5mm ID (10/pk)"" [C*213105]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 1.0mm ID (10/pk)"" [C*213110]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Long 1/16"" OD (10/pk)"" [C*213100]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Short 0.3mm ID (10/pk)"" [C*213163]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Short 0.4mm ID (10/pk)"" [C*213164]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Short 0.5mm ID (10/pk)"" [C*213165]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/16 Short 0.8mm ID (10/pk)"" [C*213168]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/8 Long 0.4mm ID (10/pk)"" [C*213204]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/8 Long 0.5mm ID (10/pk)"" [C*213205]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule 1/8 Long 0.8mm ID (10/pk)"" [C*213208]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...
Vespel/Graphite Ferrule1/16 Long 0.4mm ID (10/pk)"" [C*213104]
Made from High qualiuty DuPont polyimide/graphite blend max. temperature 400°C Recommended for GC/MS interface application ID 0.3mm for capillary column with ID 0.10–0.18mm ID 0.4mm for capillary column with ID 0.25mm ID 0.5mm for capillary column with ID 0.32mm ID 0.8mm for capillary column with ID 0.53mm ID...





eVol® XR Digitally Controlled Syringe